| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
90¡«264VAC47¡«440Hz £¬127~370VDC |
| AC Current |
1.2A/115VAC0.72A/230VAC |
| Efficiency |
69%(HPS-65-3.3); 76%(HPS-65-5); 79%(HPS-65-7.5); 79%(HPS-65-12);79%(HPS-65-13.5);
79%(HPS-65-15); 80%(HPS-65-24); 80%(HPS-65-27); 80%(HPS-65-48);
|
| Inrush Current |
Cold start 20A/115VAC40A/230VAC |
| Leakage Current |
<0.5 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
53-75W£¨3.3V:36-55W£© Hiccupe mode, recovers automatically after fault condition is removed |
| Over Voltage |
115%~135%Hiccup mode, reovers automatically after fault condition is removed |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL60950, TUV EN60950-1 |
| EMC Standard |
Design refer to EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |
| |
|
| OTHERS |
|
| Weight |
0.21Kg |
| Packing |
54pcs/14.2Kg/1.35CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation. |
| |
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |
| |
5.Mounting holes M1 and M2 should be grounded for EMI purposes. |
| |
|
| OUTPUT |
|