| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
176¡«264 VAC£»240¡«370VDC |
| AC Current |
1.2A/230VAC |
| Efficiency |
78% |
| I
Frequency Range |
47-63Hz |
| Inrush current |
COLD START 55A/230VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
150%~260%30-52A |
| |
Protection£ºShut down o/p voltage, re-power on to recover£¨30S time delay£© |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+55¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1 cycle£¬period for 60 min. Each along X,Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P£º2KVACI/P-FG£º1.5KVACO/P-FG£º0.5KVAC |
| Isolation Resistance |
I/P-O/P£¬I/P-FG£¬O/P-FG£º100M Ohms/500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
UL1012 Approved |
| EMC Standard |
Compliance to EN55022£¬EN55024£¬EN61000 |
| |
|
| OTHERS |
|
| Weight |
0.28Kg |
| Packing |
36pcs |
| |
|
| NOTE |
1.
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature |
| |
2.
Ripple is measured at 20MHz of bandwidth by using A12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor |
| |
3.
Toleranc : contain line regulation and load regulation |
| |
4.
The Power supply is considered a component which will be installed into a final equipment .The final equipment must be re-confirmed that it still needs EMC diectives. |
| |
|