| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
AC 170¡«264VAC47¡«63 Hz£»DC 240¡«370VDC |
| AC Current |
0.65A/ 230V |
| Efficiency |
82%(HSM-150-12) ;83%(HSM-150-13.5);84%(HSM-150-15);85%(HSM-150-24);85%(HSM-150-27);86%(HSM-150-48); |
| Inrush Current |
Cold start 35A/230VAC |
| Leakage Current |
< 3.5 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
110%¡«160% |
| |
Protection£ºHiccup mode£¬recovers automatically after fault condition is removed |
| Short circuit |
Protection£ºHiccup mode£¬recovers automatically after fault condition is removed |
| Over voltage |
115%~135% |
| |
Protection£ºVoltage limiting, recovers automatically after fault condition is removed |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+60¡æ£»20%¡«90 %RH(Refer to output load derating curve) |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz,2G 10min./1cycle,period for 60 min,each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P£º3KVACI/P-FG£º1.5KVACO/P-FG£º0.5KVAC |
| Isolation Resistance |
I/P-O/P£¬I/P-FG£¬O/P-FG£º100M Ohms/500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
EN60950 Approved |
| EMC Standard |
Compliance to EN55022£¬EN61000-3-2£¬-3£¬EN61000-4-2£¬3£¬4£¬5£¬6£¬8£¬11£»ENV50204£¬EN55024 |
| |
|
| OTHERS |
|
| Weight |
0.6Kg |
| Packing |
24pcs/14.4Kg/0.7CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.
Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì parallel capacitor. |
| |
3.
Tolerance: includes set up tolerance, line regulation and load regulation |
| |
4.
The Power supply is considered a component which will be installed into a final equipment.The final equipment must be re-confirmed that it still needs EMC diectives. |