| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
90¡«264VAC£¨5V£º85¡«264VAC£©47¡«63 Hz£»selected by switch 120¡«370VDC |
| Power Factor |
PF>0.93/230VAC |
| AC Current |
7A/115 VAC3.5A/230VAC |
| Efficiency |
78%£¨HSP-501-5); 84%£¨HSP-501-12); 84%£¨HSP-501-13.5);
84%£¨HSP-501-15);
85%£¨HSP-501-24); 85%£¨HSP-501-27); 86%£¨HSP-501-48);
|
| Inrush Current |
Cold start 40A /230VAC |
| Leakage Current |
<1.5mA/ 264VAC/60Hz |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
110%~130% |
| |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage |
110%~130% |
| |
Protection type: Shut down o/p voltage, re-power on to recover |
| Over Temp. |
When TSW1¡Ý80¡æ£¬TSW2¡Ý90¡æ |
| |
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+50¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
UL60950-1, EN60950-1 |
| EMC Standard |
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204£¬EN61000-6-2 |
| |
|
| OTHERS |
|
| Weight |
1.7Kg |
| Packing |
6pcs/11.3g/0.67CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation. |
| |
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must
be re-confirmed that it still meets EMC directives. |
| |
|