| SPECIFICATIONS |
|
| |
|
| INPUT |
|
| Voltage Range |
90¡«132 VAC/180¡«264VAC47¡«63 Hz;selected by switch 254¡«370VDC |
| AC Current |
4.5A/115VAC2.5A/230VAC |
| Efficiency |
74%(SKS-201-5); 79%(SKS-201-7.5); 80%(SKS-201-12); 80%(SKS-201-13.5);
81%(SKS-201-15); 83%(SKS-201-24); 83%(SKS-201-27); 84%(SKS-201-48); |
| Inrush Current |
50A/115V50A/230V |
| Leakage Current |
£¼3.5 mA/240VAC |
| |
|
| OUTPUT |
See Datasheet |
| |
|
| PROTECTION |
|
| Over Load |
115%¡«135% |
| |
Protection type: shut down o/p voltage, recovers automatically after fault
condition is removed |
| Over Voltage |
115%¡«135% |
| |
Protection: hiccup mode, recovers automatically after fault condition is removed |
| Over Temp. |
RTH3¡Ý90¡æ£¬shut down o/p voltage, recovers automatically after temperature goes down |
| |
|
| ENVIRONMENT |
|
| Working Temp., Humidity |
-10¡æ¡«+50¡æ£»20%¡«90 %RH |
| Storage Temp., Humidity |
-20¡æ¡«+85¡æ£»10%¡«95 %RH |
| Vibration |
10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
| |
|
| SAFETY |
|
| Withstand Voltage |
I/P-O/P: 1.5KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC |
| Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| |
|
| STANDARD |
|
| Safety Standard |
Design refer to UL1950 |
| EMC Standard |
Drsign refer to FCC Part15 J Conduction Class A |
| |
|
| OTHERS |
|
| Weight |
0.93Kg |
| Packing |
12pcs/12Kg/0.98CUFT |
| |
|
| NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature. |
| |
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì &47¦Ì
parallel capacitor. |
| |
3.Tolerance: includes set up tolerance, line regulation and load regulation |
| |
|
| OUTPUT |
|